1. Overview
This
life test load cabinet is designed in accordance with the requirements
for fluorescent lamp loads in standards such as IEC 60669-1:2000,
GB2099, GB7261, GB14048, GB14598.1, GB15092, GB16915, etc.
2. Technical parameters
2.1. Control power supply: AC220V±10%, 50Hz, 1000VA
2.1.1.
External input test power supply: single-phase AC220V 50/60Hz, at least
6KVA, requires external fast-response variable frequency
voltage-stabilized power supply
2.2. Test voltage: single-phase
AC0~300V Manually continuously adjustable, no voltage stabilization
function, load voltage does not exceed 280V
2.3, fluorescent lamp A load:
2.4, capacitors are equipped with two groups, one group is 70uF, the other group is 140uf
2.4.1, capacitor group: capacitance 70uF (load circuit steady-state current 6A and below) tolerance ±5%;
2.4.2, capacitor group: capacitance 140uF (load circuit steady-state current above 6A) tolerance ±5%
2.4.3,
pulse charging and discharging capacitors are used, with low loss
angle, high current di/dt resistance, and will not be damaged by impact
current
2.5, resistance and inductance part: power factor: 0.3~1 continuously adjustable;
2.6, current: AC0.5~16A continuously adjustable
RX9917 Fluorescent Lamp Load Equipment
1. Overview
This life test load cabinet is designed in accordance with the requirements for fluorescent lamp loads in standards such as IEC 60669-1:2000, GB2099, GB7261, GB14048, GB14598.1, GB15092, GB16915, etc.
2. Technical parameters
2.1. Control power supply: AC220V±10%, 50Hz, 1000VA
2.1.1. External input test power supply: single-phase AC220V 50/60Hz, at least 6KVA, requires external fast-response variable frequency voltage-stabilized power supply
2.2. Test voltage: single-phase AC0~300V Manually continuously adjustable, no voltage stabilization function, load voltage does not exceed 280V
2.3, fluorescent lamp A load:
2.4, capacitors are equipped with two groups, one group is 70uF, the other group is 140uf
2.4.1, capacitor group: capacitance 70uF (load circuit steady-state current 6A and below) tolerance ±5%;
2.4.2, capacitor group: capacitance 140uF (load circuit steady-state current above 6A) tolerance ±5%
2.4.3, pulse charging and discharging capacitors are used, with low loss angle, high current di/dt resistance, and will not be damaged by impact current
2.5, resistance and inductance part: power factor: 0.3~1 continuously adjustable;
2.6, current: AC0.5~16A continuously adjustable
Zhipinhui After-Sales Policy:
*After-Sales Hotline: +864008166687
1. Our company has assembled a team of experienced field engineers and senior technicians to promptly respond
to any equipment issues and provide after-sales maintenance.
2. Within China, within one week of new product delivery, our after-sales technical staff will install the equipment and
provide after-sales training at the customer's location, using the contact information and address provided by the customer.
3. All complaints related to product quality will be responded to within one hour. Within 3-5 hours within the province,
and within 24-48 hours outside the province, we will arrive at the customer's site,
determine the appropriate action based on the complaint, and provide after-sales repairs. (Domestic)
4. For international travel, our company can also arrange for an after-sales engineer to visit you for installation and
commissioning. Please discuss any travel and catering issues in advance.
We also provide video installation guides for you to choose from, providing you with a comprehensive and multi-faceted solution.
5. Any material costs related to product quality during the warranty period will be borne by our company.
6. During the warranty period, we will provide free repairs due to improper use or environmental factors.
The materials and accessories used for repairs will be charged at cost only.