RX9917 Fluorescent Lamp Load Equipment
1. Overview
This
life test load cabinet is designed in accordance with the requirements
for fluorescent lamp loads in standards such as IEC 60669-1:2000,
GB2099, GB7261, GB14048, GB14598.1, GB15092, GB16915, etc.
2. Technical parameters
2.1. Control power supply: AC220V±10%, 50Hz, 1000VA
2.1.1.
External input test power supply: single-phase AC220V 50/60Hz, at least
6KVA, requires external fast-response variable frequency
voltage-stabilized power supply
2.2. Test voltage: single-phase
AC0~300V Manually continuously adjustable, no voltage stabilization
function, load voltage does not exceed 280V
2.3, fluorescent lamp A load:
2.4, capacitors are equipped with two groups, one group is 70uF, the other group is 140uf
2.4.1, capacitor group: capacitance 70uF (load circuit steady-state current 6A and below) tolerance ±5%;
2.4.2, capacitor group: capacitance 140uF (load circuit steady-state current above 6A) tolerance ±5%
2.4.3,
pulse charging and discharging capacitors are used, with low loss
angle, high current di/dt resistance, and will not be damaged by impact
current
2.5, resistance and inductance part: power factor: 0.3~1 continuously adjustable;
2.6, current: AC0.5~16A continuously adjustable
RX9917 Fluorescent Lamp Load Equipment
1. Overview
This life test load cabinet is designed in accordance with the requirements for fluorescent lamp loads in standards such as IEC 60669-1:2000, GB2099, GB7261, GB14048, GB14598.1, GB15092, GB16915, etc.
2. Technical parameters
2.1. Control power supply: AC220V±10%, 50Hz, 1000VA
2.1.1. External input test power supply: single-phase AC220V 50/60Hz, at least 6KVA, requires external fast-response variable frequency voltage-stabilized power supply
2.2. Test voltage: single-phase AC0~300V Manually continuously adjustable, no voltage stabilization function, load voltage does not exceed 280V
2.3, fluorescent lamp A load:
2.4, capacitors are equipped with two groups, one group is 70uF, the other group is 140uf
2.4.1, capacitor group: capacitance 70uF (load circuit steady-state current 6A and below) tolerance ±5%;
2.4.2, capacitor group: capacitance 140uF (load circuit steady-state current above 6A) tolerance ±5%
2.4.3, pulse charging and discharging capacitors are used, with low loss angle, high current di/dt resistance, and will not be damaged by impact current
2.5, resistance and inductance part: power factor: 0.3~1 continuously adjustable;
2.6, current: AC0.5~16A continuously adjustable
Zhipinhui after-sales service
Equipment after-sales policy:
*Equipment warranty period: One Year
*After sales hotline: 4008166687
1. Our company has assembled a team of experienced on-site engineers and senior technicians who can respond promptly to any equipment issues and provide after-sales maintenance.
2. Within one week of the delivery of the new product, our after-sales technical department staff will provide installation and after-sales training for the equipment at the customer's location based on the contact information and address provided by the customer.
3. All complaints related to product quality will be responded to within 1 hour. Within 3-5 hours within the province and 24-48 hours outside the province, the customer will arrive at the scene and determine the handling measures based on the complaint situation, and carry out after-sales maintenance.
4. To better address customers' difficulties and concerns, our company promises that all maintenance personnel will be on call.
5. Any costs related to product quality during the shelf life will be borne by our company.
6. During the warranty period, we will provide free repairs due to improper use by your side or natural environment. The materials and accessories used for repairs will only be charged at cost price.