This equipment plays an important role in the development, production, and quality testing of vacuum cleaners. Let's take a look at how Guangzhou Zhipinhui Electronic Technology explains the working principles of a vacuum cleaner motor air performance tester.
1. Electrical performance parameter input test: High-precision electrical parameter instruments are used.
2. User-provided differential pressure sensor and measuring instrument for vacuum measurement.
3. Pressure equalization chamber: 18" x 18" x 10" high, conforming to the American standards ASTM F558 and F431 orifice plate method.
4. Orifice plate range: One standard orifice plate (0.5" with manual switching), accuracy ±0.05mm.
5. Tested unit: Two types of 32" and 35" hose connectors (or user-specified), or nozzle connectors.
6. Product pass/fail indicator system with audible and visual alarms.
Pass results trigger the cylinder to pop up; failure requires manual operator control of the switch.
7. Operating table height: 700mm (customizable).